5-6 TELEDYNE BENTHOS
User’s Manual P/N M-270-10, Rev. B
Frequency Add FA ##.## … ##.## or FA=##.## … ##.## FA=##.## … ##.## where ##.## is 07.00 to 15.00 in
.25 increments
Frequency Delete FD ##.## … ##.## or FD=##.## … ##.## FD=##.## … ##.## where ##.## is 07.00 to 15.00 in
.25 increments
Send Command Code SC cc ###### or SC=cc ###### SC=cc <code> where cc and <code> are one of the fol-
lowing:
ORE/Edgetech/EG&G Transponders:
cc=ED, <code>= ###### (a 6-digit octal code)
Benthos FSK Acoustic Releases:
cc=BF, <code>=##.## x y where ##.## is the frequency
in kHz , x is a letter code from A through M, and y is a
duration in seconds between 4 and 12
Benthos Smart Release (with release motor)
cc=BR, <code>=x y where x is the address of the
release and y is a release code between 0 and 65535.
Benthos Smart Modem (with burn wire)
cc=BM, <code>=x y where x is the address of the
release and y is a burn wire code between 0 and 65535.
Table 5-2 DS-7000 Write Commands (Continued)
COMMAND NAME SYNTAX RESPONSE