68 MA365 Rev. A2
Tellabs
®
6325 Edge Node 3 Reference Information
3.5.7 Environmental
Climatic and mechanical
conditions
Classification according to ETSI ETS 300 019-1:
•Storage:
ETS 300 019-1-1 class 1.2, not temperature controlled storage locations.
Transportation:
ETS 300 019-1-2 class 2.3, public transportation.
•In use:
ETS 300 019-1-3 class 3.4, stationary use at weather protected locations,
sites with heat traps.
The temperature range is limited to -5 °C to +55 ° C in case of when using
AC supply, when using CWDM transceivers or when using STM-16 trans-
ceivers.
Climatic and mechanical
conditions
The table specifies climatic and mechanical conditions of the Tellabs 6325
node during storage, transport and operation.
W-OF203/xx.x 2xLC to 2xLC
single mode fi-
ber cable
- - - - -10 70 IEC60332-1
W-OF204/xx.x 2xLC to 2xFC/
PC single mode
fiber cable
- - - - -10 70 IEC60332-1
W-OF205/xx.x 2xLC to 2xSC
single mode fi-
ber cable
- - - - -10 70 IEC60332-1
Item number Description
Wire Rated
Flammability
class
AWG
mm
2
Current Voltage Temp
DC DC Min. Max.
Parameter Storage and Transportation In use
Temperature -40 °C to +70 ° C- 40° C to +70 ° C (class 3.4).
Range limited to - 5 ° C to
+55 ° C when using:
AC supply
•CWDM transceivers
STM-16 transceivers
Humidity 10% to 100% RH, condens-
ing
5% to 100% RH, condens-
ing
Vibration Sinusoidal,
2 - 9 Hz, 3.5 mm
9 - 200 Hz, 10 m/s
2
200 - 500 Hz 15 m/s
2
Sinusoidal,
2 - 9 Hz 1.5 mm,
9 - 200 Hz 5 m/s
2