Sidekick
®
Plus Test Set
Special Connection of Leads/Strap
On shorts, the black clip is connected to the other side
of the short.
On a contact fault, the black clip is connected to the
other side of the contact (see illustration below).
On an earth, the black clip is connected to the cable
shield or earth (see illustration below).
Specifications of the RFL test are:
• Distance measurement accuracy:
±0.5% of full scale, ±1 digit
• Maximum fault resistance: 2 MΩ
• Fault check/ohms range: 0 to 19.99 MΩ
• Distance range: 0 to 61 km (0 to 199,999 ft)
• Fault current: 73 uA and 730 uA depending on fault