IBUC Operation Manual
Terrasat Communications, Inc.
Rev. A
7-24
M&C Setup
Tx System
Default values:
A SIDE IBUC:
RS485 Data Rate is 9600 baud
RS485/FSK Mode is 1 (Legacy Binary mode)
Default IP address is 192.168.1.21
Other (standby) BUC IP address is 192.168.1.22
IP gateway address is 192.168.1.1
B SIDE IBUC:
RS485 Data Rate is 9600 baud
RS485/FSK Mode is 1 (Legacy Binary mode)
Default IP address is 192.168.1.22
Other (standby) BUC IP address is 192.168.1.21
IP gateway address is 192.168.1.1
Note: RS485/FSK Mode 1 is the default setting to enable compatible modems to use
the "Legacy binary" mode to communicate with the IBUC.
General
Communication with the IBUC1+1 can be accomplished via any of five interfaces:
TCP/IP, RS232, RS485, Handheld Terminal (HHT), and FSK Link. The HHT/RS232
connections can be found on connector J1 for the A side unit, and connector J8 for the
B side unit. The IP/RS485 connections can be found on connector J3. These can be
connected to with an appropriately configured cable and terminal. FSK Link uses FSK
signals between the IBUC and modem that are multiplexed on the IFL coax cable.
TCP/IP:
Communication with the IBUC via TCP/IP can be through Telnet (ASCII) or the onboard
web server (HTTP). The IBUC uses a static IP addressing structure and does not
support DHCP. The IBUC1+1 is factory-configured as follows:
A SIDE IBUC:
IP Address 192.168.1.21
Other BUC IP Address 192.168.1.22
IP Gateway 192.168.1.1
Subnet Mask 255.255.255.0
Telnet Port 23
B SIDE IBUC:
IP Address 192.168.1.22