Table 6-9 IBUC M&C Command Set
Parameter
<value> Valid Values
(See Notes Below)
Comments Command Burst/
CSM
Mode
Config
allowed
if slave?
Default Value
HHT
[Note
4]
RS-
232
Port
RS-
485
Port
ASCII
FSK
Port
ASCII
RS-485
Binary(1)
FSK Port
Binary(1)
Telnet
Port
IBUC Operation Manual 6-12
Terrasat Communications, Inc.
Rev. A
System Configuration
Get 10MHz
detector
1=10MHz within
Range, 0=10MHz
out of range
Returns the state of
the TEN_MHZ_DET
line
C10? all na X X X X No No X
Get RS485
Address
C4A? all na X X X X No No X
Set RS485
Address
ASCII: 1 to 254
Legacy: 1 to 15
Configures the RS-
485 Address. New
address takes effect
IMMEDIATELY -
(I.e. before response
is returned).
C4A=<value> all 1 X X X X X X X
Get
RS485/FSK
Delay
C4D? all na No X X X No No X
Set
RS485/FSK
Delay
1 to 255 Sets the RS485 and
FSK Rx/Tx
Turnaround delay in
Msec.
C4D=<value> all no 20 No X X X X X X
Get
RS485/FSK
Mode
C4M? all na X X X X No No X
Set
RS485/FSK
Mode
0=ASCII Packet,
1=Legacy Binary
Sets the RS485 and
FSK ports to Legacy
Binary mode (1) or
Ascii Packet mode
(0). Receipt of this
command
IMMEDIATELY
resets the RS485
and FSK serial ports.
C4M=<value> all no 1 X X X X No No X
Get /RS485
Data Rate
C4R? all na X X X X No No X
Set RS485
Data Rate
1200, 2400, 4800,
9600, 19200, 38400,
57600, 115200
Configures the RS-
485 baud rate.
Takes effect after
reboot.
C4R=<value> all no 9600 X X X X No No X
Get Verbose
Messages
C4V? all na No X X X No No X
Set Verbose
Messages
0 = terse, 1=verbose Sets the response of
the serial and TCP
connections to terse
(for computers to
read) or verbose (for
people to read).
C4V=<value> all no 0 No X X X No No X