Table 7-10 RX 1+1 Command Set
Parameter <value> Valid
Values
(See Notes Below)
Comments Command Default Value HHT
[Note
4]
RS-
232
Port
RS-
485
Port
ASCII
FSK
Port
ASCII
Telnet
Port
Web Page
IBUC Operation Manual
Terrasat Communications, Inc.
Rev. A
7-42
computers to
read) or verbose
(for people to
read).
Get Alarm
Flags
See Table 3 for
defined error
flags
CAS? na X X X X X X
Get Alarm
Flags
(Verbose)
CAS=1 na X X X X X X
Get Model
and Serial
Number
m,s where m is
an ASCII string of
up to 19
characters
representing the
model number
and s is an ASCII
string of up to 19
characters
representing the
serial number.
(e.g. 310-10801-
0001,
TE0000000)
Query from
firmware
Constants
CCM? na X X X X X X
Get
Software
Version
n.nn Query from
firmware
Constants
CCS? na X X X X X X
Get IP
address
CIA? na X X X X X X
Set IP
address
1.0.0.0 to
223.255.255.254
Sets the TCP IP
address of the
unit.
CIA=<value> 192.168.1.254 X X X X X X
Get IP
gateway
CIG? na X X X X X X
Set IP
gateway
1.0.0.0 to
223.255.255.254
Sets the TCP IP
address of the
CIG=<value> 192.168.1.1 X X X X X X