Table 7-10 RX 1+1 Command Set
Parameter <value> Valid
Values
(See Notes Below)
Comments Command Default Value HHT
[Note
4]
RS-
232
Port
RS-
485
Port
ASCII
FSK
Port
ASCII
Telnet
Port
Web Page
IBUC Operation Manual
Terrasat Communications, Inc.
Rev. A
7-44
Trap packets on
.
Get info private label,
Model m, SN s,
Firmware Ver
n.nn, mmm dd
yyyy, tt:tt:tt
where:
private label is
set using the CPL
command
m denotes
model number,
s denotes the
serial number,
n.nn is the
software version
number,
mmm dd yyyy is
the date of
firmware,
tt:tt:tt is the time
of the firmware,
Query of unit
configuration.
COI? Terrasat Comm.,
Inc, Model 310-
10801-0001 , SN
TE0000000,
Firmware Ver. n.nn,
date, time
X X X X X X
Enter
Password
00001 - 65535 If superuser
password
entered,
superuser mode
is entered. If
main password
entered, then
normal
operation is
enabled. If read
only password
entered (1111)
CPE=<value> na X X X X X X