Table 7-10 RX 1+1 Command Set
Parameter <value> Valid
Values
(See Notes Below)
Comments Command Default Value HHT
[Note
4]
RS-
232
Port
RS-
485
Port
ASCII
FSK
Port
ASCII
Telnet
Port
Web Page
IBUC Operation Manual
Terrasat Communications, Inc.
Rev. A
7-54
Current
Alarm Low
Threshold A
(Must be less
than the High
Threshold)
current
threshold for the
A side
Get
Current
Alarm Low
Threshold B
100 to 600 ma
(Must be less
than the High
Threshold)
Returns the low
current
threshold for the
B side
IBL? X X X X X X
Set
Current
Alarm Low
Threshold B
100 to 600 ma
(Must be less
than the High
Threshold)
Sets the low
current
threshold for the
B side
IBL=<value> 250 X X X X X X
Get
Current
Alarm High
Threshold A
100 to 600 ma
(Must be greater
than the Low
Threshold)
Returns the high
current
threshold for the
A side
IAH? X X X X X X
Set
Current
Alarm High
Threshold A
100 to 600 ma
(Must be greater
than the Low
Threshold)
Sets the high
voltage current
for the A side
IAH=<value> 500 X X X X X X
Get
Current
Alarm High
Threshold B
100 to 600 ma
(Must be greater
than the Low
Threshold)
Returns the high
voltage current
for the B side
IBH? X X X X X X
Set
Current
Alarm High
Threshold B
100 to 600 ma
(Must be greater
than the Low
Threshold)
Sets the high
voltage current
for the B side
IBH=<value> 500 X X X X X X
Alarm/Temp Log History
Monitor
Alarm
History
Alarm Flag, CR,
LF for the last (up
to) 100 alarms in
order as they
occurred.
Returns an
ASCII string for
each record in
history. String
format is 0xLLLL
where LL is the
AHI? na X X X X X X