Table 6-9 IBUC M&C Command Set
Parameter
<value> Valid Values
(See Notes Below)
Comments Command Burst/
CSM
Mode
Config
allowed
if slave?
Default Value
HHT
[Note
4]
RS-
232
Port
RS-
485
Port
ASCII
FSK
Port
ASCII
RS-485
Binary(1)
FSK Port
Binary(1)
Telnet
Port
IBUC Operation Manual 6-26
Terrasat Communications, Inc.
Rev. A
Get Transmit
Power Up
Delay
Returns value of
Transmit Power Up
Delay.
TSD? all na X X X X No No X
Set Transmit
Power Up
Delay
0 to 500 in 1 sec.
steps.
Sets transmit Power
Up delay to selected
duration. Delay
timer is only used on
power up. Turn TX
off until delay
completed, then turn
on if appropriate.
TSD=<value> all no 0 X+- X X X No No X
Get Transmit
state at BUC
power Up
Reports State at Pwr
Up
TSP? all na X X X X No No X
Set Transmit
state at BUC
power Up
1=On, or 0=Off Set transmitter to
this state at power
up.
TSP=<value> all no 1 X X X X No No X
Get MUTE
state
Reports whether
MUTE is asserted or
not.
TST? all na X X X X X X X
Set MUTE
state
1=Transmitter On, or
0=Transmitter Off
Turns on or off the
SSPA.
TST=<value> all no 1 X X X X X X X
Get BUC
High Temp
Shutdown
Returns the value of
the high temp
shutdown
enable/disable.
TTS? all na X X X X X X X
Set BUC
High Temp
Shutdown
1=Enables or
0=Disables
Enables or Disables
the high temp
shutdown when
temperature
exceeds ratings. A
zero disables the
automatic shutdown.
Caution when
setting this to zero
as the unit can be
damaged.
TTS=<value> all no 1 X X X X X X X
Alarm/Temp Log History
Monitor
Alarm History
Alarm Flag, CR, LF
for the last (up to)
100 alarms in order
as they occurred.
Returns an ASCII
string for each
record in history.
String format is
AHI? all na X X X X No No X