G.2.5 Smoke No./ HCT
Calling up the function:
Measurements Smoke No./HCT .
Enter the smoke tester no./smoke numbers/oil derivative:
The function is only available if the chosen fuel is an oil.
1
Sm. tester no. Enter pump number .
2
Smoke# 1 Enter the value .
3
Repeat step
2
for the other smoke numbers and oil derivative as required.
Entering the heat carrier temperature:
Heat carrier Enter the value .
Copy the values to the Flue gas menu:
The smoke number/HCT-values are not displayed in the menu Flue gas. They can,
however, be printed or stored in a measurement protocol, together with the measure-
ment values of a flue gas measurement. In the menu
Memory / Location, the smoke
count/WTT values can be displayed in the measurement program, printed or trans-
ferred to a Pocket PC/PC.
OK Copy readings .
- The
Measurements menu is opened.
G.2.6 Differential pressure
The gas pressure set (0554 1203) must be connected.
Dangerous mixture of gases
Danger oof eexplosion!
Make sure there are no leaks between the sampling point and the meas-
uring instrument.
Do not smoke or use naked flames during measurement.
Do not measure for longer than 5 min, as the drift of the pressure sensor means that
the readings could be outside the tolerance limits.
Calling up the function:
Measurements Differential press. .
OKOK
OK
OKChange
OKChange
OKChange
OKOK
G. Measuring
G.2 Measurements
39