3.5 Power Consumption Over Recommended Operating Conditions
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
f
HCLK
= 220MHz
350 for PGE
Package
V
CC
digital supply current (operating mode) mA
f
VCLK
= 110MHz, 375 for ZWT
Flash in pipelined Package400
mode, V
CCmax
I
CC
LBIST clock rate =
V
CC
Digital supply current (LBIST mode) mA
400
110MHz
Peak PBIST ROM clock TBD
VCC Digital supply current
mA
frequency = 110MHz
(PBIST mode)
RMS 260
I
CCPLL
VCCPLL digital supply current (operating mode) V
CCPLL
= V
CCPLLmax
10 mA
I
CCIO
V
CCIO
Digital supply current (operating mode. No DC load, V
CCmax
15 mA
Single ADC 15
operational,
V
CCADmax
I
CCAD
V
CCAD
supply current (operating mode) mA
Both ADCs 30
operational,
V
CCADmax
Single ADC 3
operational,
AD
REFHImax
I
CCREFHI
AD
REFHI
supply current (operating mode) mA
Both ADCs 6
operational,
AD
REFHImax
read operation 34
V
CCPmax
program, V
CCPmax
37
read from 1 bank 55
I
CCP
V
CCP
supply current mA
and program
another bank,
V
CCPmax
erase, V
CCPmax
27
48 Device Operating Conditions Copyright © 2012, Texas Instruments Incorporated