Loading...
Premier 48, 88, 168 & 640 Installation Manual Factory Defaults
INS176 29
4. Factory Defaults
Menu Option Default
User Codes
Setup Users User 00 (Engineer) 1234
User 01 (Master) 5678
All Other Users Not Defined
1. Zone Setup
Zones Types 1 Entry/Exit 1
2 Guard Access
3 - 8 Guard
All Other Zones Not Used
Zone Areas All Zones Area A
Zone Text All Zones Not Defined
Zone Chime All Zones Silent
Zone Mask All Zones On
2. Area Programming
Timers Exit Delay 030 Seconds
(All Areas) Entry Delay 1 045 Seconds
Entry Delay 2 045 Seconds
2
nd
Entry Dly 000 Seconds
Bell Delay
000 Minutes
Bell Duration 015 Minutes
Coms Delay 000 Seconds
Part Bell Dly 000 Seconds
Arming Modes All Areas
Entry/Exit
Area Arm Suites All Suites
No Areas
Area Suite Text All Suites
Not Defined
Suite Arm Modes All Suites
Timed
Area Options 1: Auto Part Arm
No Areas
2: Part Arm Instant
No Areas
3: Part Arm Silent
No Areas
4: Remote Arm All Areas
5: Remote Disarm
All Areas
6: Panel Tamper
Area A
7: Bell Tamper
Area A
8: Auxiliary Tamper
Area A
9: Panel Speaker
All Areas
10: Bell & Strobe op
All Areas
11: Alarm Eng Reset
No Areas
12: Confirmation Reset
All Areas
13: Tamper Eng Reset
All Areas **
14: Anti-code Reset
All Areas
15: ATS Path Faults
Area A
16: Arm With No ATS
No Areas **
17: AC Mains Fail
Area A
18: Arm With AC Fail Area A
19: Full Arm Coms
All Areas
20: Part Arm Coms
No Areas
21: Unarm Fire Coms
No Areas
22: Unarm Tamp Coms
All Areas **
23: Auto Arm Areas
No Areas
24: Area A Foyer
No Areas
25: Log Part Omits
No Areas
26: Multi Knock Area
No Areas
27: UDL Keypad
All Areas
28: Auto Chime (C2A)
No Areas
29: Confirm In Entry
No Areas
30: Conf. After Entry
All Areas
31: Part Arm Enabled
ALL Areas
32: Bell Squawk
No Areas
33: Fob After Entry
All Areas
34: Armed = Coms
No Areas
35: 2 Wire Smoke
No Areas
36: Faults Eng Reset
All Areas **
37: No ATS Eng Reset
All Areas **
38: AC Fail Eng Rst
All Areas **
39: Mask When Armed
All Areas
Area Text All Areas
Not Defined
Menu Option Default
3. Global Options
System Timers 1: Exit Settle Time 008 Seconds
2: Global Bell Dly. 000 Minutes
3: Global Bell Dur. 015 Minutes
4: Double Knock Dly 007 Seconds
5: Beam Pair Time 060 Seconds
6: Activity Delay 024 Hours
7: Abort Delay 180 Seconds
8: Courtesy Time 060 Seconds
9: Defer Arming By 030 Minutes
10: Auto Arm Delay 030 Minutes
11: Menu Time Out 180 Seconds
12: Pulse Period 1 010 Seconds
13: Pulse Period 2 020 Seconds
14: Pulse Period 3 030 Minutes
15: ATS Fault Delay 000 Minutes
16: AC Off Delay 005 Minutes
17: Batt Test Period 024 Hours
18: Batt Test Time 010 Seconds
19: Soak Test Time 014 Days
20: Service Interval 000 Weeks
21: Test Call Every 024 Hours **
22: Min Random Time 000 Seconds
23: Max Random Time 060 Seconds
24: Door Strike Time 005 Seconds
25: Zone Response 008 x 8mSec.
26: Keypad PA Delay 060 Seconds
27: Confirmation Dly 060 Minutes
28: Warning Delay 000 Minutes
29: Keypad Lock time 090 Seconds
30: Eng. Log Off Dly 060 Minutes
31: Fire Bell Delay 000 Minutes
32: Forced Entry Dly 005 Seconds
33: Supervision Time 030 Minutes
34: Poll IP Every 000 Minutes
System Config. 00: Bell on Arm Fail No Bell
01: Bell is an SCB SAB
02: Clock is 12Hr 24Hr
03: Manual BST/GMT Auto
04: Hide Armed Areas View
05: Area Bell Time Global
06: 24Hr Omit Local Global
07: Leave Omits Remove
08: Enforce Com Delay Override
09: NVM is Locked Unlocked
10: Engineer Only User + Engineer
11: Chime Visible Audible
12: Omit Tampers NO YES **
13: Offline Printing Online
14: View Act. Fault Hide
15: Hide Exit Errors Hide
16: No Code Tamp Enable
17: Code Tamp Alarms Locks **
18: Areas 1-8 & I-P A-H & I-P
19: Man. Area Select Auto
20: Normal Text Predictive
21: Zone Short = Active Tamper
22: R/R=Silence/RST Reset Only
23: User Code Latch Pulse
24: Test Call = CT4 Timed
25: Batt Test = Disarm Timed
26: Bell = 2nd Alarm 1st Alarm
27: SNDR = 2nd Alarm 1st Alarm
28: Conf. = Delayed Instant
29: Abort = User Reset Eng.
30: Manual AV Output Auto