EasyManua.ls Logo

Texecom PREMIER 88 - 6 Specifications; Control Panel

Texecom PREMIER 88
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Premier 48, 88, 168 & 640 Installation Manual Specifications
INS176 99
6. Specifications
Control Panel
Power supply
Mains Supply Voltage:
230V
AC (±10%)
Maximum Total Current Rating
16.5VAC, 40VA transformer:
2.0ADC
Ripple <5%
Power Supply 2A
Battery Charging Current 750mA
Maximum Available Current 1.25A
PD6662 Rated Output See Page 11
Standby Battery Capacity 7Ah to 18Ah
Recharge Time <24Hrs
Low Battery Fault 10.5V
Deep Discharge Protection 9.5V
Electrical
Current Consumption 48/88/168
Quiescent
Alarm (Nothing Connected)
70mA
70mA
Current Consumption 640
Quiescent
Alarm (Nothing Connected)
160mA
160mA
Fuses
Mains (2.0A
DC)
Battery
Auxiliary
Bell
Network 1 (48/88/168)
Network 2 (168)
Networks 1 to 8 (640)
500mA, 250V, 20mm
1.6 Amp, 250V, 20mm
1 Amp, 250V, 20mm
1 Amp, 250V, 20mm
1 Amp, 250V, 20mm
1 Amp, 250V, 20mm
900mA, 250V PTC
Data Network
4-wire standard 7/0.2
alarm cable up to 500m
Star, Daisy Chain or any
combination of the two
Remote Keypads
Premier 48
Premier 88
Premier 168
Premier 640
Up to 4
Up to 8
Up to 16
Up to 64
Expanders
Premier 48
Premier 88
Premier 168
Premier 640
Up to 4
Up to 8
Up to 16
Up to 64
Output Modules
Premier 48
Premier 88
Premier 168
Premier 640
Up to 2
Up to 4
Up to 8
Up to 32
Zones
Premier 48
Premier 88
Premier 168
Premier 640
8 expandable to 48
8 expandable to 88
8 expandable to 168
0 expandable to 640
EOL Resistor Values
EOL Resistor
Contact Resistor
Fault Resistor
0 - 1k
1k1 to 4k
4k1 to 5k6
5k7 to 8k
8k1 to 20k (30k)
21k+ (30k+)
2k2 (3k3)
4k7 (3k3)
2k2
Zone Short
Zone Secure
Zone Fault
Zone Active
Zone Mask
Zone Tamper
Digicom Outputs
Outputs 1 to 8
100mA switched to 0V
Panel Outputs
Outputs 1 & 2 (48/88/168/640)
Outputs 3 & 4 (88/168/640)
Output 5 (88/168/640)
500mA switched to 0V
500mA switched to 12V
3 Amp Relay
Siren Outputs
Bell Trigger
Strobe Trigger
1A switched to 0V
1A switched to 0V
Speaker Output
Minimum load 8
Environmental
Operating Temperature
-10°C (+14°F) to
+55°C (+131°F)
Storage Temperature
-20°C (-4°F) to
+60°C (+140°F)
Maximum Humidity 95% non-condensing
EMC Environment
Residential
Commercial
Light Industrial
Industrial
Physical
Housing Metal
Dimensions (W x H x D)
305mm x 405mm x
100mm x 2mm Steel
Battery Compartment
Up to two 12V 7.0Ah
batteries or one 12V 18Ah
battery
Packed Weight 5.5 Kg

Table of Contents

Other manuals for Texecom PREMIER 88

Related product manuals