Premier 48, 88, 168 & 640 Installation Manual Programming the Control Panel
INS176 39
5.2 Area Programming
Timers
1,")" 1BX
/"/,$/**&+$
Yes
Yes
/"/,$/**&+$
&*"/0
Use the SCROLL key to
select an area
Yes
Enter a new timer value
e.g. 025 = 25 Seconds
???
Yes
Press YES to move to
the required timer group
or press RESET to move
backwards e.g. YES
F5&1")6
8;8" ,+!_0`
F5&1")6
8;8" ,+!_0`
F+1/69")6
F8:=" ,+!_0`
Reset
F
+
1
/6
9
"
)
6

8:8
" ,+
!_
0
`
These groups of ‘Area’ timers control timing and delay
functions for areas A - D (Premier 48), A - H (Premier 88) and
A - P (Premier 168 and 640). Each timer can be programmed
for any value between 000 and 999.
1 - Exit Delay- for Areas A to D (A to H) (A to P)
When the area exit mode is programmed as ‘Timed’ this timer
controls the delay between the user initiating the exit mode
for the selected area and the area actually.
2 - Entry 1 Delay - for Areas A to D (A to H) (A to P)
If the area is armed and an ‘Entry/Exit 1’ zone is activated,
this timer will start and the entry tone will be heard. If the area
is not disarmed before this timer expires, the ‘2
nd
Entry Delay’
timer will start.
3 - Entry 2 Delay - for Areas A to D (A to H) (A to P)
If the area is armed and an ‘Entry/Exit 2’ zone is activated,
this timer will start and the entry tone will be heard. If the area
is not disarmed before this timer expires, the ‘2
nd
Entry Delay’
timer will start.
4 - 2
nd
Entry Dly - for Areas A to D (A to H) (A to P)
When the area ‘Entry Delay 1 or 2’ timer expires, this timer will
start and an Internal alarm will occur. If the area is still not
disarmed before this timer expires, an Intruder alarm will then
occur.
5 - Bell Delay - for Areas A to D (A to H) (A to P)
This timer controls the delay between an Intruder alarm
occurring in the selected area and the ‘Bell/Strobe’ output
activating.
6 - Bell Duration - for Areas A to D (A to H) (A to P)
This timer controls the duration of the ‘Bell’ output after an
Intruder alarm has occurred in the selected area and any
programmed ‘Bell Delay’ has expired.
7 - Coms Delay. for Areas A to D (A to H) (A to P)
This timer controls the delay between an Intruder alarm
occurring in the selected area and the communicator reporting to
the Alarm Receiving Centre.
8 - Part Bell Dly. for Areas A to D (A to H) (A to P)
When the selected area is ‘Part Armed’ this timer controls the
delay between an Intruder alarm occurring in the selected
area and the ‘Bell/Strobe’ output activating, the internal
sounders will also sound during this time as a warning.