EasyManua.ls Logo

Texecom PREMIER 88 - Area Suite Text; Suite Arm Modes

Texecom PREMIER 88
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Premier 48, 88, 168 & 640 Installation Manual Programming the Control Panel
INS176 41
Area Suite Text
1,")" 1BX
/"/,$/**&+$
Yes
/"/,$/**&+$
/"2&1""51
Yes
3
def
/"/,$/**&+$
&*"/0
9
/*2&1"9/"
No
????
9
L!&1"51F
Use keys 1 - 8 to select
an Area Arm Suite or use the
SCROLL key to search e.g. 4
4
ghi
<
/"/*2&1"<
Yes
"!1&*""11&+$
!&1"51FL
Use keys 0 - 9 to program
text the same way that a
mobile phone works
Press NO to edit the
Area Arm Suite text
Text may be assigned to the Area Arm Suites to allow the user
to select the suites by description instead of number. Up to 16
characters of text can be programmed for each suite.
Example
Text descriptions for the Area Arm Suites could be useful
where more than one suite has been defined. The user
wishes to arm areas A and B at night but is not too sure
which suite to select.
Areas ‘A and B’ would be assigned to ‘Area Arm Suite 1’
(see page 40 for details)
When the user wants to arm the system at night, ‘Area
Arm Suite 1’ would be selected
Text will be displayed to confirm that the selected suite is
correct i.e. ‘Bedtime Setting’
Areas A and B are automatically selected for armed
Text is programmed in a similar way to mobile phones. Select
characters by pressing the corresponding key the
appropriate number of times (to select a character on the
same key, press
to move the cursor along).
Suite Arm Modes
1,")" 1BX
/"/,$/**&+$
Yes
/"/,$/**&+$
2&1"/*,!"0
Yes
4
ghi
/"/,$/**&+$
&*"/0
Yes
2&1"9/*6B
&*"!"5&1
1
2&1":/*6B
F+1/6Z5&1
2&1":/*6B
&*"!"5&1
Use keys 1 - 5 to select
an arming mode
e.g. 1 = Entry/Exit
Use the SCROLL key
to select a suite
The way that an Area Arm Suite arms when selected, can be
configured for any of the following options:
1 - Entry/Exit
The suite will arm after the ‘Entry/Exit’ door has been closed
and the ‘Exit Settle’ timer has expired.
2 - Exit Term.
The suite will arm after the ‘Entry/Exit’ door has been closed,
the ‘Exit Terminator’ button has been pressed and the ‘Exit
Settle’ timer has expired.
3 - Timed Exit (Default for All Areas)
The suite will arm after the programmed ‘Exit Time’ has
expired.
If an ‘Exit Terminator’ zone is activated at any point
during the exit mode, any remaining exit time is
cancelled and the area will arm immediately.
4 - Instant
The suite will arm instantly.
5 - Deferred
The suite will arm after the programmed ‘Exit Time’ has
expired. However, if any zones not on the exit route are
activated during the exit mode, the ‘Exit Time’ is restarted.

Table of Contents