Premier 48, 88, 168 & 640 Installation Manual Programming the Control Panel
INS176 91
Log Event Description
MANUAL TEST CALL A Manual test call has been initiated
MIC ## TESTED Microphone ## on the Audio Verification Module has been tested
No RF Signal ### The Wireless receiver has detected a signal loss from zone ###
Panel Line Fault The control panel line fault input has been activated
PART Armed Area ? has been Part Armed
PART 1 Armed Part Arm 1 has been selected
PART 2 Armed Part Arm 2 has been selected
PART 3 Armed Part Arm 3 has been selected
POWERED UP System Power Up (without doing a factory restart)
PROG. END The Engineer has logged out of the Programming menu
PROG. START An Engineer code has been entered
PSUac ## Alarm An expander input programmed as PSU Monitor control panel has detected an AC Mains failure
PSUbat## Alarm An expander input programmed as PSU Monitor control panel has detected a Battery fault
PSUvol## Alarm An expander input programmed as PSU Monitor control panel has detected a 12V Output failure
PSUTam## Alarm An expander input programmed as PSU Monitor control panel has detected a Tamper condition
QUICK Armed Quick Arm from keypad #,#
R/Bat ## Alarm The Wireless receiver has detected a low battery signal from device ##
Radio Jammed The Wireless receiver has detected an attempt to jam its radio signal
RADIO PAD LOST The Radio-Pad has no signal or has lost communications with the control panel
REARM LOCK ### Zone ### has locked out after reaching its re-arm limit (after causing an alarm)
RECENT Armed Area ? has been armed recently
Redcare Line Fault The Redcare has detected a line fault
REMOTE Armed Area ? was armed using the Wintex UDL software
REMOTE Disarmed Area ? was disarmed using the Wintex UDL software
Remote PC Reset A reset has been performed by the remote download PC
Remote Reset A reset has been performed using the ‘Remote Reset’ input
Redcare Reset A reset has been performed by the Redcare
RKP #,# MEDICAL A Medical alarm (7 & 9) has occurred from keypad number #,#
RKP #.# FIRE A Fire alarm (4 & 6) has occurred from keypad number #,#
RKP #,# AUD PA An Audible PA alarm (1 & 3) has occurred from keypad number #,#
RKP #,# SIL PA A Silent PA alarm (1 & 3) has occurred from keypad number #,#
RKP #,# Tamper The cover of keypad #,# has been removed
RKP #,# LOST Keypad ## has been lost from the network
RKP LOCKED #,# Keypad #,# has been locked out from too many invalid key presses
TAG ## User ## has presented their Prox TAG
TESTED ### Zone ### has been tested
TEST FAIL ###) Zone ### has failed its Soak test
TIME Armed Area ? was armed automatically using one of the control timers
TIME CHANGED The control panel Date has been changed
TIME Disarmed Area ? was disarmed automatically using one of the control timers
TUBE ### Alarm Zone ### (programmed as Tube Key) has caused an alarm
USER ## User ## has entered their code
USER CODE CHANGED A User code has been altered or added
USER CODE DELETED A User code has been deleted
User Reset A reset has been performed using a User code
WALK Tst start The Walk Test mode has been initiated
Zone ### Alarm Zone ### has been activated
Zone ### Tamper Zone ### has caused a Tamper alarm
Zone ### Restore Zone ### has restored to its normal condition
Zone ### Omitted Zone ### has been omitted
Zone ### Un-Omit Zone ### has been reinstated
Zone ### Test Start Zone ### has been put on test
Zone ### Test End Zone ### has been removed from test