S.M.A.R.T. Information
On the Disks Information screen, the status of each disk will be displayed in the
Status column. Clicking on an OK or Warning link will display the S.M.A.R.T
Information window for that particular disk.
You may also perform disk SMART test, simply to click “Test” to start with. The
result is only for reference and system will not take any action from its result.
S.M.A.R.T. Information
Item Description
Tray Number Tray the hard disk is installed in.
Model Model name of the installed hard disk.
Power ON Hours Count of hours in power-on state. The raw value of this attribute
shows total count of hours (or minutes, or seconds, depending on
manufacturer) in power-on state.
Temperature Celsius The current temperature of the hard disk in degrees Celsius
Reallocated Sector
Count
Count of reallocated sectors. When the hard drive finds a
read/write/verification error, it marks this sector as "reallocated"
and transfers data to a special reserved area (spare area).
This process is also known as remapping and "reallocated" sectors
are called remaps. This is why, on a modern hard disks, you can
not see "bad blocks" while testing the surface - all bad blocks are
hidden in reallocated sectors. However, the more sectors that are
reallocated, the more a decrease (up to 10% or more) can be
noticed in disk read/write speeds.
Current Pending Sector Current count of unstable sectors (waiting for remapping). The
raw value of this attribute indicates the total number of sectors
waiting for remapping. Later, when some of these sectors are read
successfully, the value is decreased. If errors still occur when
reading sectors, the hard drive will try to restore the data, transfer
When the Status shows Warning, it usually means there are bad sectors on the
hard disk. It is shown only as a precaution and you should consider changing the
drives.
NOTE
49

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thecus N5500 and is the answer not in the manual?

Thecus N5500 Specifications

General IconGeneral
RAID levels0, 1, 5, 6, 10, JBOD
Storage drive size3.5 \
Hot-swap drive baysYes
Storage drive capacity- GB
Supported file systemsEXT3, XFS, ZFS
Storage drive interfaceSerial ATA
Total installed storage capacity0 TB
Maximum supported storage capacity10 TB
Number of storage drives installed0
Number of storage drives supported5
Flash memory128 MB
Internal memory1 GB
Internal memory typeDDR2
Processor frequency1.86 GHz
Supported network protocolsTCP/IP, CIFS/SMB, AFP, NFS, HTTP, HTTPS, FTP, FTP-SSL/TLS
USB 2.0 ports quantity6
Ethernet LAN (RJ-45) ports2
Dimensions (WxDxH)190 x 240 x 230 mm
Management platformLinux
Compatible operating systemsWindows 7/2000/XP/2003/Vista UNIX/Linux Mac OS 9 / X
Operating temperature (T-T)5 - 40 °C
Operating relative humidity (H-H)0 - 80 %
Power supply unit (PSU) capacity200 W
Weight and Dimensions IconWeight and Dimensions
Weight7200 g