EX-TRAFIRE
®
45SD
Operator Manual, Revision T-58-68
ERROR CODES
H03 System operation failed
H04 No pilot arc established possibly due to a loss of current�
H05 Consumables in torch failed to separate during pilot arc�
H06 Over - temperature alarm
H07 Over - current alarm
H08 Torch inspection / cap sensor (The cutting torch is missing or not connected�)
H09 Consumables in Place check
H10 Internal communication error remote control
H11 Missing phase or no input voltage (single phase power supply only)
H13 Air pressure alarm
L - The input pressure is too low
H - The input pressure is too high
H04: After prolonged periods of use, the consumables may become worn and influence the contact between the nozzle
and electrode� This may lead to the pilot arc failing to ignite and generate the H04 alarm� To clear the alarm,
depress the trigger again, this should generate the pilot arc or the system will automatically reset the alarm
after 15 seconds�
H10: Contact your distributor