Manual 0-2899 3-1 DESCRIPTION
SECTION 3:
DESCRIPTION
3.01 Scope
The purpose of this section is:
• To familiarize the service technician with the capabilities and limitations of the equipment,
• To provide an overall understanding which will allow the technician, in turn, to properly train customer oper-
ating personnel.
3.02 Specifications/Design Features
Input Power (See Note 1)
Power Sensing
Input Power Cable
Output Current
Power Supply Gas Filtering Ability
Ambient Temperature
Duty Cycle 35% 60%
DC Voltage 78 vdc 89 vdc
Current 30 Amps 22 Amps
Gas Type
Gas specifications
Maximum Input Gas Pressure
Operating Gas Pressure
Gas Flow Requirements
CutMaster 38 Power Su
l
S
ecifications
120 VAC (± 10%), Single-Phase, 50/60 Hz
208 - 230 VAC (± 10%), Single-Phase, 50/60 Hz
Automatic Voltage Selection. See Note 1.
Cord with plug, for 120VAC, 20-Amp Single-Phase input power.
20-30 Amps, continuously variable
Particulates to 20 Microns
CutMaster 38 Power Su
l
Dut
C
cle
Note 2
104° F (40° C)
n/a %
n/a vdc
n/a Amps
SL 60 Torch Gas Re
uirements
Compressed Air
Clean, dry, oil-free (Note 3)
125 psi / 8.6 bar
2
. Duty Cycle is the percentage of time the system can be operated without overheating. Duty cycle
is reduced if primary input voltage (AC) is low or the DC voltage is higher than shown in this chart.
3
. Air supply must be free of oil, moisture, and other contaminants. Excessive oil and moisture may
cause double-arcing, rapid tip wear, or even complete torch failure. Contaminants may cause poor
cutting performance and rapid electrode wear. Optional filters provide increased filtering capabilities.
65 psi / 4.5 bar
300 scfh / 141.5 lpm
Notes
1
. Power supply accepts 120-230 VAC input power. No manual switching is required.