OPERATING MANUAL TW63 MOUNTING THE MACHINE
ThyssenKrupp Aufzugswerke GmbH
5.4 Terminal connecting information for motors complying with BV 6531 –
22
for three-phase motors with direct current brake winding, type A4
S1 Normally open contact in the winding
RS Min. 22 Ω, max. 47 Ω
CS Min. 0.22 µF/250 V~, max. 0.47 µF/250 V~
CA Starting capacitor for fan
RB Varistor SIOV-S14K275
The low speed winding is to be designed as a direct current
winding or placed in a brake in-line circuit.