2
FOREWORD
General Handling Precautions
Before starting work or operation, be sure to check that the instrument is
functioning correctly with normal performance.
Do not aim the instrument directly into the sun
Aiming the instrument directly into the sun can result in serious damage to the eyes.
Damage to the instrument could also result from exposing the instrument’s objective lens to
direct sunlight. The use of a solar filter is suggested to alleviate this problem.
Setting the instrument on a tripod
When mounting the instrument on a tripod, use a wooden tripod when possible. The
vibrations that may occur when using a metallic tripod can effect the measuring precision.
Installing the tribrach
If the tribrach is installed incorrectly, the measuring precision could be effected.
Occasionally check the adjusting screws on the tribrach. Make sure the base fixing lever is
locked and the base fixing screws are tightened.
Guarding the instrument against shocks
When transporting the instrument, provide some protection to minimize risk of shocks.
Heavy shocks may cause the measurement to be faulty.
Carrying the instrument
Always carry the instrument by its handgrip.
Exposing the instrument to extreme heat.
Do not leave the instrument in extreme heat for longer than necessary. It could adversely
affect its performance.
Sudden changes of temperature
Any sudden change of temperature to the instrument or prism may result in a reduction of
measuring distance range, i.e when taking the instrument out from a heated vehicle. Let
instrument acclimate itself to ambient temperature.
Battery level check
Confirm battery level remaining before operating.
Memory back up
The back-up battery built in the instrument needs to be charged approximately 24hrs.
before using it for the first time after purchase. Connect the fully charged battery to the
instrument in order to charge the back-up battery.
Taking the battery out
Leaving the instrument without the battery for more than an hour will cause the memorized
data to be lost, due to low voltage of the back-up battery. Connect the battery as soon as
possible or execute RAM back-up.
No responsibility
TOPCON Corporation has no responsibility for loss of data stored in the memory in case
unexpected accidents.
Battery Cover
Completely close the battery cover before using the GPT-7000i.If the battery cover is not
completely closed, the GPT-7000i will not operate normally, regardless of whether the
battery or the external power source is used.
If the battery cover is opened while the GPT-7000i is in operation, operation will
automatically be suspended.
Power OFF
When turning off the power, be sure to turn off the GPT-7000i’s power switch.
Do not turn off the power by removing the battery.
Before removing the battery, press the power switch and confirm that the power is off. Then
remove the battery.
While using the external power source, do not turn off the GPT-7000i with the switch on the
external power source.
If the above-mentioned operating procedure is not followed, then, the next time that power
is turned on, it will be necessary to reboot the GPT-7000i.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Topcon GPT-7000i Series and is the answer not in the manual?

Topcon GPT-7000i Series Specifications

General IconGeneral
BrandTopcon
ModelGPT-7000i Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals