75
5 CHECK AND ADJUSTMENT
When screws A, B and C are turned clockwise (the direction for tightening them), the laser pointer, as
seen on the target from the standpoint of the GPT-7000i, will move in the direction shown in the
drawing.
About30°
The direction of the laser pointer
Adjustment screws
As seen from above
About30°
Tighten the 3 screws so that they are equally tight.