6.Installthefueltankcaptothefueltank.
ReplacingtheFuelLine
ServiceInterval:Every1,000hours
Replacethefuellineafterevery1000hours.Iffuelleaksfrom
theline,replaceitimmediately.
ElectricalSystem
Maintenance
ServicingtheTraction
InterlockSwitch
Usethefollowingprocedureiftheswitchneedsadjustment
orreplacement.
1.Makesuretheengineisoff.
2.Removethecontrolpanel.
3.Engagethetractionlever.
Figure38
1.Tractionlever2.Interlockswitch
4.Loosentheinterlockswitchmountingfasteners(Figure
38).
5.Placea1.6mm(0.062inch)thickshimbetweenthe
tractionleverandtheinterlockswitch(Figure38).
6.Tightentheinterlockswitchmountingfasteners.
7.Engagethetractionleverandcheckthegap.The
normaloperatingrangeisbetween0.76to3.05mm
(0.03to0.12inches).Withthetractionleverengaged,
verifythattheswitchlosescontinuity.Replacethe
switch,ifrequired.