5.Starttheengineandrotatethecamhexinboth
directionstodeterminethemidpositionofthe
neutralspan.
6.Tightenthelocknutsecuringtheadjustment.
7.Shutofftheengine.
8.Removethesupportblocksandlowerthe
machinetotheshopoor.T estdrivethe
machinetoensurethatitdoesnotmovewhen
thetractionpedalisinneutral.
CoolingSystem
Maintenance
CoolingSystemSafety
Swallowingenginecoolantcancausepoisoning;
keepoutofreachfromchildrenandpets.
Dischargeofhot,pressurizedcoolantortouching
ahotradiatorandsurroundingpartscancause
severeburns.
Alwaysallowtheenginetocoolatleast15
minutesbeforeremovingtheradiatorcap.
Usearagwhenopeningtheradiatorcap,and
openthecapslowlytoallowsteamtoescape.
Donotoperatethemachinewithoutthecovers
inplace.
Keepyourngers,handsandclothingclearof
rotatingfananddrivebelt.
CheckingtheCooling
System
ServiceInterval:Beforeeachuseordaily
Cleananydebrisoffoftheradiator(Figure56).
g195255
Figure56
1.Radiator
Cleantheradiatorhourlyifconditionsareextremely
dustyanddirty;refertoCleaningtheCoolingSystem
(page48).
Thecoolingsystemislledwitha50/50solution
ofwaterandpermanentethyleneglycolanti-freeze.
Checkthecoolantlevelatthebeginningofeachday
beforestartingtheengine.