3.Rotatethestrainerbowlcounterclockwiseand
removethebowlandscreenfromthebodyof
thestrainer(Figure54).
Note:Removethestrainerbowlbyhand.
Note:Replacethegasketorscreenorbothif
thesepartsarewornordamaged.
g311411
Figure54
1.Strainerbowl3.Screen
2.Gasket4.Strainerbody
4.Allowanyresidualchemicalsolutiontodrain
fromthestrainerbody.
Note:Disposeofthewastesolutionaccording
tolocalcodesandthechemicalmanufacturer's
instructions.
5.Useasoft-bristlebrushandcleanwatertoclean
thescreenandbowl.
6.Installthescreenintothestrainerbody(Figure
54).
7.Installthegasketandstrainerbowlontothe
strainerbody,andhandtightenthebowl(Figure
54).
CleaningtheSprayerNozzles
ServiceInterval:Aftereachuse
1.Rotatethenozzlecap90°counterclockwiseand
removethecapfromthenozzlebody(Figure
55).
g311414
Figure55
1.Nozzlebody
3.Sprayertip
2.Strainer
4.Nozzlecap
2.Removethesprayertipandstrainerfromthe
nozzlebody(Figure55).
Note:Replaceanywornordamagednozzle
parts.
3.Useasoft-bristlebrushandcleanwatertoclean
thenozzletipandstrainer.
4.Assemblethestrainerintothenozzlebody
(Figure55).
5.Assemblethesprayertipintothenozzlecap
(Figure55).
6.Installthetipandcapontothenozzlebody
(Figure55).
Note:Usetheslottorotatetheatomizer(Figure
56)ofthesprayertipforward(in-linewiththe
ow-regulatorcaseofthenozzlebody).
45