ADJUSTMENT
3 - 14
3.3.4 Scanner related adjustment
[A] Image distortion
Fig. 3-10
<Procedure>
(1) While pressing [0] and [5] simultaneously,
turn the power ON.
(2) Press [FAX] to make a copy of any image on
a sheet of A3/LD paper.
(3) Key in [308] and press the [START] button to
move the carriage to the adjustment position.
(4) Make an adjustment in the order of step 1
and 2.
•Step 1
- In case of A:
Tighten the mirror-3 adjustment screw
(CW).
- In case of B:
Loosen the mirror-3 adjustment screw
(CCW).
•Step 2
- In case of C:
Tighten the mirror-1 adjustment screw
(CW).
- In case of D:
Loosen the mirror-1 adjustment screw
(CCW).
(5) Apply the screw locking agents to the
adjustment screws. (2 areas)
Recommended screw lock agent
Manufacturer: Three Bond
Product name: 1401E
Fig. 3-11
Fig. 3-12
Feeding direction
Feeding direction
Step 1
A
Step 2
C
B
D
Carriage-2
Adjustment screw for the mirror-3 (Rear)
Adjustment screw
for the mirror-1 (Rear)
Carriage-1