3
© 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455
ADJUSTMENT
3 - 19
[F] Top margin
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode)
(2) Open the original cover or RADF.
(3) Press [FAX] to make a copy at the mode of A3/LD, 100%, Text/Photo and the lower drawer
(Refer to *).
(4) Measure the blank area E at the leading edge of the copied image.
(5) Check if the blank area E is within the range of 3 ± 0.5 mm.
(6) If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode) (Key in the code [430]) [START]
(Key in a value (acceptable values: 0 to 255))
Press the [ENTER] or the [INTERRUPT] button (stored in memory).
(“100% A” is displayed.)
* The larger the adjustment value is, the wider the blank area becomes (approx. 0.04 mm/
step).
Fig. 3-17
E
Feeding direction

Table of Contents