3
© 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455
ADJUSTMENT
3 - 53
[B] Adjustment of the magnification ratio of the lens
Notes:
Perform this adjustment only when the lens unit is taken off or replaced.
Make sure that the primary scanning reproduction ratio (printer section) is correct before this
adjustment.
(1) Place a ruler on the original glass (in the primary scanning direction) and make a copy on A4/LT-
sized paper at 100% reproduction ratio.
(3) If each mark on the rulers differs, perform the adjustment with the following procedures.
<Procedure>
(2) Compare the copied ruler with the actual
ruler.
Fig. 3-38
(1) Take off the original glass and lens cover.
(2) Loosen 4 screws fixing the lens unit.
Fig. 3-39
Feeding Direction
Actual rulerCopied ruler
Screw
Lens unit