e-STUDIO205L/255/305/355/455 © 2009 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 60
(9) Attach the developer material cover and
tighten 2 screws.
Notes:
1. After the developer material has been
replaced, adjust the auto-toner sensor.
(See P.3-2 "3.2 Adjustment of Auto-
Toner Sensor".)
2. When installing the developer unit upper
cover, make sure that the side seal
comes between the developer unit upper
cover and rubber seal on the cover.
Fig. 3-54
Fig. 3-55
Developer
material cover
Side seal
Rubber seal
Developer unit
upper cover