ERROR CODE AND TROUBLESHOOTING
6 - 49
[E725] Stop jam at the read sensor
1. Clean the read roller if it is stained.
2. Is the read sensor working? (Perform the input check: 03-[FAX]ON/[7]/[G])
* If it is working properly, proceed to 6. If not, check 3 to 5 below.
3. Check if the connector CN75 on the RADF board is disconnected from the read sensor or the
harnesses are open circuited. Correct if any.
4. Replace the read sensor.
5. Replace the RADF board.
6. Replace the read roller if it is worn out.
[E731] Stop jam at the exit sensor
1. Clean the exit roller if it is stained.
2. Is the exit/reverse sensor working? (Perform the input check: 03-[FAX]ON/[7]/[E])
* If it is working properly, proceed to 6. If not, check 3 to 5 below.
3. Check if the connector CN4 on the RADF board is disconnected from the exit/reverse sensor or
the harnesses are open circuited. Correct if any.
4. Replace the exit/reverse sensor.
5. Replace the RADF board.
6. Replace the exit roller if it is worn out.
[E860] RADF jam access cover open
1. Close the RADF jam access cover if it is opened. Remove if there is any original before closing it.
2. Is the RADF jam access cover switch working? (Perform the input check: 03-[FAX]ON/[7]/[C])
* If it is working properly, proceed to 6. If not, check 3 to 5 below.
3. Check if the connector CN8 on the RADF board is disconnected from the RADF jam access
cover switch or the harnesses are open circuited. Correct if any.
4. Replace the RADF jam access cover switch.
5. Replace the RADF board.
[E870] RADF open jam
1. Close the RADF if it is opened. Remove if there is any original before closing it.
2. Is the RADF opening/closing sensor working? (Perform the input check: 03-[FAX]ON/[7]/[D])
* If it is working properly, proceed to 6. If not, check 3 to 5 below.
3. Check if the connector CN75 on the RADF board is disconnected from the RADF opening/
closing sensor or the harnesses are open circuited. Correct if any.
4. Replace the RADF opening/closing sensor.
5. Replace the RADF board.
6. Is the RADF opening/closing sensor adjusted within the specified range?
[E871] Cover open jam in the read ready status
1. Close the RADF jam access cover or the front cover if they are opened in the read ready status.
2. IIs the RADF jam access cover sensor working? (Perform the input check: 03-[FAX]ON/[7]/[C])
3. Check if the connector CN75 on the RADF board is disconnected from the RADF jam access
cover sensor or the harnesses are open circuited. Correct if any.
4. Replace the RADF jam access cover sensor.
5. Replace the RADF board.