EasyManua.ls Logo

Toshiba RAS-B10J2KVG-E - Fan Motor; Horizontal Louver

Toshiba RAS-B10J2KVG-E
137 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. Part name
Procedures
Remarks
Fan motor
Hexagon screw driver
Vertical louver
Cross flow fan
Fan motor
Screws
Motor band
5
1) Follow the procedure item 3 and 4 .
2) Loosen the set screw of the cross flow fan.
3) Remove 2 fixing screws of the motor band.
4) Pull the motor band and the fan motor
outward.
3.5 mm
Cross flow fan
Set screw
Fan motor
Body back
Horizontal louver
6
1) Remove shaft of the horizontal louver
from the back body. (First remove 2 the
center shafts then remove the other shafts.)
Horizontal louver
Drain pan
<To re-installation>
- Check the type name of fan motor.
- Keep connector position and arrange fan
motor wires follow figure.
For SJM-240-25
(45°)
Fan motor
connector
(45°)
Fan motor
connector
For SJM-240-35
Fan motor wires
Fan motor wires
For ICF-340-30-6
(45°)
Fan motor
connector
Fan motor wire
FILE NO. SVM-19001
- 111 -

Table of Contents

Other manuals for Toshiba RAS-B10J2KVG-E

Related product manuals