Power supply input wiring diagram for 1:1 Outdoor unit
Power supply input at Indoor unit Terminal Block (Recommend)
1. The power supply must be same as the rated of air conditioner.
2. Prepare the power source for exclusive use with air conditioner.
3. Circuit breaker must be used for the power supply line of this air conditioner.
4. Be sure to comply power supply and connecting cable for size and wiring method.
5. Every wire must be connected f rmly.
6. Perform wiring works so as to allow a general wiring capacity.
7. Wrong wiring connection may cause some electrical part burn out.
8. Incorrect or incomplete wiring is carried out, it will cause an ignition or smoke.
9. This product can be connected to main power supply.
Connection to fixed wiring : A switch which disconnects all poles and has a contact separation at least 3mm must be
incorporated in the fixed wiring.
CAUTION
Indoor
Terminal
Block
Power input
Outdoor
Terminal
Block
Chassis
Chassis
Power input at Outdoor Terminal Block (Optional)
Indoor
Terminal
Block
Power input
Outdoor
Terminal
Block
Chassis
Chassis
FILE NO. SVM-19001
- 72 -