10. INSTALLATION PROCEDURE
10-1. Installation Diagram of Indoor and Outdoor Units
1
(Attach to the front panel.)
Air f lter
Hook
Installation
plate
Hook
65 mm or more
300 mm or more
300 mm or more
Right
Rear 
right
Bottom
right
Rear
left
Bottom left
Left
Insulate the refrigerant pipes separately 
with insulation, not together.
6 mm thick heat resisting
polyethylene foam
Vinyl tape
Apply after carrying
out a drainage test.
Saddle
Extension drain hose
(Not available, provided 
by installer)
Shield pipe
C mm or more
F mm or more
E mm or more
D mm or more
 
C mm or more
Make sure to run the drain hose sloped 
downward.
Do not allow the drain hose to get slack.
Refrigerant piping 
must be protected from 
physical damage.
Install a plastic cover or 
equivalent.
Cut the piping 
hole sloped 
slightly.
2
3
6
4
Batteries
Flat head 
wood screw
Remote control 
holder
Wireless remote control
 RAS-05,07J2AVG-E
RAS-10,13J2AVG-E
RAS-16J2AVG-E
C
600 600
D 400 600
E45 100
F 100 100
RAS-18J2AVG-E
Before installing the wireless remote controller
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (-) positions.
3   Batteries
2   Wireless remote controller
AC
L
For the rear left, bottom left and left piping
Wall
Cut out a piece of SPACER from indoor 
unit packaging box, roll it and insert 
between the indoor unit and wall to tilt 
the indoor unit for better operation.
The auxiliary piping can be connected to 
the left, rear left, rear right, right, bottom 
right or bottom left.