6-1. Indoor Unit
6-2. Outdoor Unit
No. Type name Specifications
1  Compressor
RAS-05,07,10
KSK75D43UEZA 3-Phases (6-Poles) ;    550W
RAS-13 KSK89D53UEZ
3-Phases (6-Poles) ;    620W
RAS-16,18
 KSN108D22UFZ 3-Phases (6-Poles) ;    750W
2  Fan Motor  WDF-340-A43-1  DC 140-340V ; 43W
3  Pulse Modulating Valve (PMV) coil  PQ-M10012-000313  DC 12V
4 4-Way valve coil  DXQ-939  AC 220-240V
5  Reactor
RAS-16,18
 CH-69-Z-T  L = 19mH, 10A
6  Suction temp. sensor  (TS sensor)  (Inverter attached)
10kΩ at 25°C
7  Discharge temp. sensor  (TD sensor)  (Inverter attached)
62kΩ at 20°C
8  Outside air temp. sensor  (TO sensor)  (Inverter attached)
9  Heat Exchanger temp. sensor  (TE sensor)  (Inverter attached)
10kΩ at 25°C
10  Terminal block  (5 poles)  JXO-5B
 AC 250V, 20A
Parts name
10kΩ at 25°C
No. Typeype Specificat
1  Fan Motor (for indoor) 
RAS-B05,07,10,13
SJM-240-25 AC 220~240V, 25W
RAS-B16
SJM-240-35 AC 220~240V, 35W
2 Room temp. sensor (TA-sensor) (-) 10kΩ at 25°C
3 Heat exchanger temp. sensor (TC-sensor) (-) 10kΩ at 25°C
4 Heat exchanger temp. sensor (TCJ-sensor)
(-)
Parts name
5
Louver motor
24BYJ48-ST
Output (Rated) 4 phase, DC12V
10kΩ at 25°C
6. SPECIFICATIONS OF ELECTRICAL PARTS
RAS-18
ICF-340-30-6 DC 340V, 42W