Item
2. Indoor fan
motor control
Operation flow and applicable data, etc.
<In cooling operation>
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
Description
* Symbols
UH : Ultra High
H : High
M+ : Medium+
M : Medium
L+ : Low+
L: Low
L- : Low–
UL : Ultra Low
SUL : Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
(Fig. 1)
(Fig. 2)
(Table 1)  Indoor fan air flow rate
+2.5
Ta
[
°C
]
+2.0
+1.5
+1.0
+0.5
Tsc
a
b
c
d
e
M+(WC)
*3
*4
*5
L(W7)
Air volume AUTO
L
L+
M
M+
H
W7
(L + M) / 2
WA
(M + H) / 2
WD
Indication
Fan speed
Fan speed setup
COOL ON
AUTO
MANUAL
*3 : Fan speed = (M + –L) x 3/4 + L
*4 : Fan speed = (M + –L) x 2/4 + L
*5 : Fan speed = (M + –L) x 1/4 + L
(Linear approximation 
from M+ and L)
Fan speed level
Cooling Heating Cooling Heating
Cool Heat Dry Fan speed Air flow rate Fan speed Air flow rate
(rpm)
m
3
/hr
Fan speed Air flow rate 
(rpm) m
3
/hr
Fan speed Air flow rate 
(rpm) m
3
/hr
(rpm)
m
3
/hr
WF UH 1050 484 1050 618 1080 504 1080 640
WE UH H 1050 484 1050 618 1080 504 1080 640
WD H M+ UH 1020 465 1000 581 1050 484 1030 603
WC M+ H 970 432 910 514 1000 452 940 536
WB
M
M+ 890 380 830 454 910 393 850 469
WA M
M
810 327 830 454 820 334 850 469
W9 L+ 810 327 720 373 820 334 730 380
W8 L+ L L+ 700 255 620 298 710 262 620 298
W7 L L- 600 190 580 268 600 190 580 268
W6 L- L 570 170 580 268 570 170 580 268
W5 UL UL L- 550 157 550 246 550 157 550 246
W4 UL 550 157 550 246 550 157 550 246
W3 SUL SUL 540 151 520 224 540 151 520 224
W2 SUL 520 138 520 224 520 138 520 224
W1 500 125 500 209 500 125 500 209
RAS-B07J2KVG-E
Mode
RAS-B05J2KVG-E