EasyManua.ls Logo

Toshiba RAS-B10J2KVG-E - Page 28

Toshiba RAS-B10J2KVG-E
137 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOTE :
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
INDOOR UNIT
T1 Temp. measurement
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Allowable height
difference : 12m
Allowable pipe length
P
Pressure measurement
Gauge attaching port
Vacuum pump connecting port
Deoxidized copper pipe
Outer dia. : 1
2.7mm
Thickness : 0.8mm
Pulse Modulating
valve at liquid side
TD
4-way valve
Compressor
K
SN108D22UFZ
TS
T2
Outdoor heat
exchanger
Temp. measurement
Propeller fan
OUTDOOR UNIT
Muffler
Muffler
TE
TC
TA
Max. : 20
m
Min.
: 2m
Chargeless :
1
5
m
TO
Strainer
RAS-18J2KVG-E / RAS-18J2AVG-E
Strainer
Refrigerant amount : 0.88kg
FILE NO. SVM-19001
- 28 -

Table of Contents

Other manuals for Toshiba RAS-B10J2KVG-E

Related product manuals