6.1.2 Putting out signals of arbitrary frequencies
 : Speed reach setting frequency
 : Speed reach detection band
Function
When the output frequency becomes equal to the frequency set by  ± , an ON or OFF is
generated.
[Parameter setting of frequency and detection band]
Title Function Adjustment range Default setting
 Speed reach setting frequency ~ Hz 
 Speed reach detection band ~ Hz 
[Parameter setting of output terminal selection]
Title Function Adjustment range Example of setting

Output terminal function selection 2
(OUT2)
~
(RCH (specified speed ON signal) )
or
(RCH (specified speed OFF
signal) )
Note: To put out signals to OUT1, select the parameter .
1) If the detection band value + the set frequency is less than the designated
frequency
Output frequency [Hz]
Speed reach setting frequency : Inverse
Time [s]


ON
OFF

+


ON
OFF
0
()
Speed reach setting frequency
P24-OUT1 terminals
P24-OUT2 terminals (Default setting)
FLA-FLB-FLC terminals
2) If the detection band value + the set frequency is more than the designated
frequency
Output frequency [Hz]
Time [s]


ON
OFF

+


Speed reach setting frequency : Inverse
ON
OFF
0
(
)
Speed reach setting frequency
P24-OUT1 terminals
P24-OUT2 terminals (Default setting)
FLA-FLB-FLC terminals