EasyManua.ls Logo

Toshiba TOSVERT VF-AS1 - Torque Control; Torque Command; Speed Limits in Torque Control Mode; Torque Bias and Load Sharing Gain

Toshiba TOSVERT VF-AS1
328 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E6581528
F-39
6
6.24 Torque control
For details, refer to Instruction Manual (E6581331) specified in Section 6.42.
6.24.1 Torque command
 : V/f control mode selection
 : Torque command selection
 : VI/II input point 1 setting
 : VI/II input point 2 setting
 : RR/S4 input point 1 setting
 : RR/S4 input point 2 setting
 : RX input point 1 setting
 : RX input point 2 setting
 : AI2 input point 1 setting
 : AI2 input point 2 setting
 : VI/II input point 1 rate
 : VI/II input point 2 rate
 : RR/S4 input point 1 rate
 : RR/S4 input point 2 rate
 : RX input point 1 rate
 : RX input point 2 rate
 : Prohibition of rotation in any direction other than the specified one (F or R)
 : Opelation panel torque command
For details, refer to Instruction Manual (E6581331) specified in Section 6.42.
6.24.2 Speed limits in torque control mode
 :
Forward speed limit input selection
 :
Forward speed limit input level
 :
Reverse speed limit input selection
 :
Reverse speed limit input level
 :
Speed limit (torque=0) center value
reference selection
 :
Speed limit (torque=0) center value
 :
Speed limit (torque=0) band
For details, refer to Instruction Manual (E6581331) specified in Section 6.42.
6.24.3 Torque bias and load sharing gain
 : Load portion torque input selection
 : Tension torque bias input selection
 : Load sharing gain input selection
1) Selection of torque bias input
Torque bias
Torque control
+
+
+
Speed control
[Parameter setting]
Title Function Adjustment range Default setting

Load portion torque input
selection
:Disabled
:VI/II (voltage/current input)
:RR/S4 (potentiometer/voltage input)
:RX (voltage input)
: enabled
:2-wire RS485 input enabled
:4-wire RS485 input enabled
:Communication option input enabled
:Optional AI1 (Differential current input)


Hoisting torque bias input
(valid only when =)
~ % 