6.33.16 Regenerative power ride-through control level
 : Regenerative power ride-through control level
Function
This parameter is used to set the operation level of the regenerative power ride-through control and the
deceleration stop. (Refer to Section 5.18.2.)
Title Function Adjustment range
Default
setting
 Regenerative power ride-through control level
~ % for 500V class.
~ % for 575V class
~ % for 690V class

Note1: Set this parameter at a value of +5% or more. Or the braking time of regenerative power
ride-though control could be extremely shorter. This setting is not necessary if  is set to  (auto
mode).
Note2: When power on or reset operation, the power supply voltage is detected. If the setting value of parameter
 is too low, the setting value is automatically adjusted to stabilize the performance.
Note3: For , 100% value 500V ( if  is set in)
575V ( Default setting or if  is set in )
690V ( if  is set in )
6.33.17 Braking answer waiting time
 : Braking answer waiting time
Function
This parameter is used to set the waiting time for answer from system (Input terminal function setting:
System supporting sequence (BA: Braking answer , )). After start of operation, if no answer is
received in set time (), the inverter trips ().
Title Function Adjustment range Default setting
 Braking answer waiting time
:Disabled
~ sec.

6.33.18 VI/II analog input wire breakage detection level
 : VI/II analog input wire breakage detection level
Function
The inverter will trip if the VI/II value remains below the specified value for 0.3 seconds or moreThe
message “” is displayed.
=: Disabled ·········· The detection function is disabled.
=~ ·············· The inverter will trip if the VI/II value remains below the specified value for 0.3
seconds or more.
Title Function Adjustment range Default setting
 VI/II analog input wire breakage detection level
:None
~ %
