TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany
Page 44 of 68 TR - ECE - BA - DGB - 0065 - 03 03/11/2016
3 Technical data
3.1 Electrical characteristics
Supply voltage ...................................................
11-27 V DC, twisted in pairs and shielded
Current load .......................................................
< 200 mA at 11 V DC, < 110 mA at 27 V DC (unloaded)
Total resolution ..................................................
24 bit (optional 25 bit)
Number of steps / revolution ............................
Standard ........................................................
4.096 revolutions (12 bit)
Expanded ......................................................
Baud rate (adjustable) .......................................
125 kBaud, line length up to 500 m
250 kBaud, line length up to 250 m
500 kBaud, line length up to 100 m
Station addresses ..............................................
0 – 63, adjustable via DIP switches
Transmission .....................................................
twisted in pairs and shielded copper cable
CAN DeviceNet™ interface ...............................
CAN field bus interface (opto-isolated)
Data transmission .........................................
CAN bus driver (ISO/DIS 11898)
Terminating resistor ..........................................
121 ohm, selectable via DIP switches
Special features .................................................
Programming of the following parameters via the
- Direction of rotation via bus
- Output code (binary, gray)
- Measuring length in steps
- Measuring length in revolutions
- Preset adjustment via bus
Immunity to disturbance ................................
Transient emissions ......................................