Causes of faults and remedies
TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany
Page 68 of 68 TR - ECE - BA - DGB - 0065 - 03 03/11/2016
8.3 Other faults
Position skips
of the measuring
system
Loose contacts in the
wiring
Check all the cabling and wiring used for connecting the
encoder.
Vibrations, impacts and shocks, e.g. on presses, are
dampened with "shock modules". If the error recurs
despite these measures, the measuring system must be
replaced.
Perhaps isolated flanges and couplings made of plastic
help against electrical faults, as well as cables with twisted
pair wires for data and supply. Shielding and wire routing
must be performed according to the DeviceNet-
specification.
Extreme axial and
radial load on the
shaft may result in a
scanning defect.
Couplings prevent mechanical stress on the shaft. If the
error still occurs despite these measures, the measuring
system must be replaced.