6.1.5 I/O Instance (polled IO)
Input Instance
Number
Name
1
Position value
Input Data Format
Instance
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1
0
D07
Low Byte Position value
D00
1
D15
.
D08
2
D23
.
D16
3
High Byte Position value
7. AO
6. AO
5. AO
4. AO
3. AO
2. AO
1. AO
D24
AO = Auxiliary Output