20
T60X
1 Shower
inoperable, no
water flow.
2 Water too hot.
3 Water
temperature
cycling hot/cool at
intervals.
4 Water too cool
or cold.
1.1 No mains water
supply to shower.
1.2 Unit malfunction.
2.1 Not enough water
flowing through the
shower.
2.2 Blockage in supply.
2.3 Increase in ambient
water temperature.
3.1 Heater cycling on
temperature limiter.
4.1 Too much flow.
4.2 Water pressure
below minimum required
(see rating label).
4.3 Reduction
in ambient water
temperature.
4.4 Interrupted power
supply.
4.5 Electrical
malfunction or safety
cut-out operated.
1.1.1 Check if isolating valves are fully open.
Check if a blockage in inlet filter or in pipework.
1.2.1 Have unit checked. Contact Customer
Experience.
2.1.1 Increase flow rate via temperature
control.
2.1.2 Blocked shower head — clean or replace
blocked sprayplate in shower head.
2.2.1 Check if stop valves are fully open. Check
if a blockage in inlet filter.
2.3.1 Readjust flow rate to give increased flow.
2.3.2 Select economy power.
3.1.1 See Water too hot causes 2.1, 2.2 and
2.3 and their appropriate actions. If it continues,
contact Triton Customer Experience.
4.1.1 Reduce flow rate via temperature control.
4.2.1 Is water supply mains or tank fed?
4.2.2 If tank fed, replumb to mains water
supply or see 4.2.4.
4.2.3 If mains fed, make sure that mains
stopvalve is fully open and that there are no
other restrictions in the supply while shower is
in use, or see 4.2.4.
4.2.4 Fit pump to give minimum pressure (see
rating label). Contact Customer Experience for
advice.
4.3.1 Readjust flow rate to give reduced flow.
4.3.2 Select HIGH power.
4.4.1 Blown fuse or circuit breaker. Check
supply. Renew or reset fuse or circuit breaker. If
it fails again, consult a qualified electrician.
4.4.2 Power cut. Check other appliances and if
necessary, contact local Electricity Supply Co.
4.5.1 Have unit checked by suitably qualified
electrician or contact Triton Customer
Experience.
FAULT FINDING
IMPORTANT: Switch OFF the electricity at the mains supply and remove the circuit fuse
before removing the cover from the shower while attempting any fault finding inside
the unit.
Problem Cause Action

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Triton T60X and is the answer not in the manual?