21
T60X
5 Shower varies
from normal
temperature to cold
during use.
6 Pressure relief
device has operated
(water ejected from
PRD tube).
5.1 Water pressure has
dropped below minimum
required
6.1 Blocked shower
head.
6.2 Twisted/blocked
flexible shower hose.
6.3 Shower head
not removed whilst
commissioning.
5.1.1 Wait until the water pressure resumes to
normal.
6.1.1 Clean or replace blocked sprayplate in
shower head and then fit new PRD.
6.2.1 Check for free passage through hose.
Replace the hose if necessary and fit new PRD.
6.3.1 Fit new PRD. Commission unit with
shower head removed.
FAULT FINDING
Problem Cause Action
Y-001-A
In the unlikely event of unit failure other than detailed in the fault nding page,
please contact Customer Experience for advice.
N-003-A
Note: Identify cause of operation before fitting new PRD unit.
When fitting a new PRD, follow the commissioning procedure.
It is advised all electrical maintenance/repairs to the shower
should be carried out by a suitably qualified person.