Why does TrojanLabel Trojan 2 Industrial Equipment show error (1) after pressing Calibrate Web?
- RRichard HaleySep 12, 2025
If the web status display of your TrojanLabel Industrial Equipment shows Error (1) after pressing Calibrate Web, it could be due to loose label material or loose winders. Try reducing tension on the unwinder or fixate the core to the material. Tighten winders by turning the knobs.