Troubleshooting
9 Troubleshooting
Errors Cause Remedy
No suction power (fumes/gases are
not extracted).
The exhaust hose is not connected to
the Atmos.
Connect the exhaust hose to the
Atmos.
The exhaust hose is not connected to
the machine.
Connect the exhaust hose to the
industrial laser machine.
Damage to the exhaust hose. Replace the exhaust hose.
Suction power too low (fumes/gases
are hardly extracted).
Filter is full. Replace filter. Dispose of old filters
properly.
Damage to the exhaust hose. Replace the exhaust hose.
The exhaust hose is not correctly
connected to the Atmos.
Check the fit of the exhaust hose on
the Atmos and, if necessary, reinsert it
into the suction intake.
The exhaust hose is not correctly
connected to the machine.
Check the fit of the exhaust hose on
the machine and, if necessary, reinsert
it into the suction intake.
Clean gas path is constricted. Check the clean gas path and correct
any faults if necessary.
Suction path is constricted. Check the suction path and correct any
faults if necessary.