EasyManua.ls Logo

TYM T1054 - Checking Fuel System and Replacing Fuel Filter; How to Bleed Fuel System

TYM T1054
204 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 - 11
5
MAINTENANCE
Fuel ller port
J10O519A
6. CHECKING FUEL SYSTEM AND REPLACING FUEL FILTER
Run the engine for approx. 5 min
-
utes and check for proper opera-
tion through the engine oil warn-
ing lamp on the instrument clus-
ter. Then, stop the engine. (This
warning lamp should be turned
off while the engine is running.)
Check the oil level with the dip
-
stick again. If still insufficient,
add more.
FUEL
Use only low sulfur or ultra low sulfur
diesel fuel.
(1) Fuel ller port
When checking the fuel system
or fueling, keep ammable items,
such as a lit cigarette, away from
the tractor.
The tractor may catchre.
DANGER
(2) How to bleed fuel system
It is necessary to bleed the system
under the following conditions:
- The engine is stopped due to the
empty fuel tank.
- The lter or pipe is removed.
Bleed the system according to the
following procedures:
Disconnect the connector.
Press the priming pump repeat
-
edly to bleed the system.
Priming pump
J10O520A
Connector

Table of Contents

Related product manuals