Fuel ller port
J10O519A
6. CHECKING FUEL SYSTEM AND REPLACING FUEL FILTER
④
Run the engine for approx. 5 min
-
utes and check for proper opera-
tion through the engine oil warn-
ing lamp on the instrument clus-
ter. Then, stop the engine. (This
warning lamp should be turned
off while the engine is running.)
⑤
Check the oil level with the dip
-
stick again. If still insufficient,
add more.
FUEL
Use only low sulfur or ultra low sulfur
diesel fuel.
(1) Fuel ller port
►
When checking the fuel system
or fueling, keep ammable items,
such as a lit cigarette, away from
the tractor.
The tractor may catch re.
•
•
DANGER
(2) How to bleed fuel system
It is necessary to bleed the system
under the following conditions:
- The engine is stopped due to the
empty fuel tank.
- The lter or pipe is removed.
Bleed the system according to the
following procedures:
①
Disconnect the connector.
②
Press the priming pump repeat
-
edly to bleed the system.
Priming pump
J10O520A
Connector