7 - 10
TROUBLESHOOTING
TROUBLE cAUSE AcTION
Motor
Theblowerspeedistoosloworthereis
nospeedatall
Normal motor
Abnormal motor
Air leak
•
•
•
Cloggedairinlet
Defectiveblowerspeedcontroldial
Defectivemotor
Open wiring
Leakagefromduct
•
•
•
•
•
Remove
Replace the switch
Replace
Check
thewiringandfuse
Checkandtighten
•
•
•
•
•
Theblowerspeedcannotbeadjusted
Normal motor
Abnormal motor
Itproducesabnormalnoise
Regular noise
Irregular rattling noise
•
•
•
•
Defectiveblowerspeedcontroldial
Defectivemotor
Interference with pulley
•
•
•
Replace the switch
Replace
Adjust
thecompressor'sdirection
•
•
•
Compressor clutch
It won't operate
Itisoperatedatsomepoint
Itisoperatedwhenpushingitwith
hands
There
isnowiringdefect
•
•
•
Defectivewiring
Excessiveclutchclearance
Lowvoltage
Internal failure
•
•
•
•
Check the wiring
Adjust
Check
the battery
Replace
•
•
•
•
It slips
Slipping when rotating
•
Lowvoltage
Oilonclutchdisc
Internal failure
•
•
•
Check the battery
Clean
Replace
•
•
•

Table of Contents