TROUBLESHOOTING
TROUBLE cAUSE AcTION
Motor
Theblowerspeedistoosloworthereis
nospeedatall
Normal motor
Abnormal motor
Air leak
Cloggedairinlet
Defectiveblowerspeedcontroldial
Defectivemotor
Open wiring
Leakagefromduct
Remove
Replace the switch
Replace
Check
thewiringandfuse
Checkandtighten
Theblowerspeedcannotbeadjusted
Normal motor
Abnormal motor
Itproducesabnormalnoise
Regular noise
Irregular rattling noise
Defectiveblowerspeedcontroldial
Defectivemotor
Interference with pulley
Replace the switch
Replace
Adjust
thecompressor'sdirection
Compressor clutch
It won't operate
Itisoperatedatsomepoint
Itisoperatedwhenpushingitwith
hands
There
isnowiringdefect
Defectivewiring
Excessiveclutchclearance
Lowvoltage
Internal failure
Check the wiring
Adjust
Check
the battery
Replace
It slips
Slipping when rotating
Lowvoltage
Oilonclutchdisc
Internal failure
Check the battery
Clean
Replace