EasyManuals Logo

UNICORECOMM Unicore User Manual

Default Icon
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
Command and Log Reference
37
ID
Field
Description
Symbol
Example
GLONASS=38 to 74
GALILEO = 75 to 119
BD2 = 161 to 197
16
pdop
Position dilution of precision
x.x
1.5
17
hdop
Horizontal dilution of precision
x.x
0.9
18
vdop
Vertical dilution of precision
x.x
1.2
19
*xx
Checksum
*hh
*3F
20
[CR][LF]
Sentence terminator
[CR][LF]
6.1.8 GPGST Pseudorange measurement noise statistics
This command is used to log pseudorange measurement noise statistics, these
values will be sent to the positioning results to present statistical qualities of the
positioning solution.
This log reflects the positioning accuracy of the GPGGA, except for the RMS field.
The RMS field, since it specifically relates to pseudorange inputs, does not represent
carrier-phase based positions.
Recommend Input:
Output 1Hz GPGST message from current serial port:
GPGST 1
Output 1Hz GPGST message from com2:
GPGST COM2 1
LOG output:
$GPGST,141451.00,1.18,0.00,0.00,0.0000,0.00,0.00,0.00*6B
Table 6-9: GPGST Message Description