- 32 -
ANT
START
STOP
START P.
COM
PHOTO1
PHOTO2
EDGE1
EDGE2
COM
FCA1
FCC1
FCA2
FCC2
COM
+24VDC
COM (-)
+24VDC (TEST)
LOCK
LIGHT
24V
M1 M2
COURTESY
LIGHT
CONTACT
ANT-
L1 L2 L3 L4 L5 L6 L7 L8 L9 L10L11 K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 Z1 Z2 Z3 Z4 Z5 Z6 B1 B2
L1 Antenna
L2 Antenna shield
L3 Openingcontrolfortheconnectionofcontrol
devices with N.O. contact
L4 Openingcontrolsforpedestrianaccessforthe
connectionofcontroldeviceswithN.O.contact
L5 Stop command. N.C. contact
L6 Common (-)
L7 Photocellstype1.N.C.contact
L8 Photocellstype2.N.C.contact
L9 Safetyribbonstype1(xed).N.C.contact
L10 Safetyribbonstype2(mobile).N.C.contact
L11 Common (-)
Z1 - Z2 Lowvoltagelight(24V)
Z3 Motor 1 (OPENING)
Z4 Motor 1 (CLOSING)
Z5 Motor 2 (OPENING)
Z6 Motor 2 (CLOSING)
B1 - B2 230VACcourtesylightorashinglight
POW+ +24Vpowersupply
POW- Powersupply(-)
BAT+ +poleoftheoptionalbatterypack(code161212)
ortheECO-LOGICbatterybox
BAT- -poleoftheoptionalbatterypack(code161212)or
theECO-LOGICbatterybox
L Power phase 230 VAC
N Neutral 230 VAC
RECEIVER Pluginreceiver
ADI ADIinterface
OVERLOAD It shows that there is an overload on accessories
powersupply
MAINS It shows that the control unit is power supplied
F1 2,5A
K1 Open limit switch motor 1
Encoder
motor 2
K2 Close limit switch motor 1
K3 Open limit switch motor 2
Encoder
motor 1
K4 Close limit switch motor 2
K5 Common (-)
K6 Poweroutput+24Vdcforphotocellsandother
accessories
K7 Commonforaccessoriespowersupply
K8 Photocell/opticaledgeTXpowersupplyfor
functionaltest
K9 - K10 LOCK 12V
5.14 - ELECTRIC CONNECTIONS