ENGLISH
- 32 -
ANT
START
STOP
START P.
COM
PHOTO1
PHOTO2
EDGE1
EDGE2
COM
FCA1
FCC1
FCA2
FCC2
COM
+24VDC
COM (-)
+24VDC (TEST)
LOCK
LIGHT
24V
M1 M2
COURTESY
LIGHT
CONTACT
ANT-
L1 L2 L3 L4 L5 L6 L7 L8 L9 L10L11 K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 Z1 Z2 Z3 Z4 Z5 Z6 B1 B2
L1 Antenna
L2 Antenna shield
L3 Openingcontrolfortheconnectionofcontrol
devices with N.O. contact
L4 Openingcontrolsforpedestrianaccessforthe
connectionofcontroldeviceswithN.O.contact
L5 Stop command. N.C. contact
L6 Common (-)
L7 Photocellstype1.N.C.contact
L8 Photocellstype2.N.C.contact
L9 Safetyribbonstype1(xed).N.C.contact
L10 Safetyribbonstype2(mobile).N.C.contact
L11 Common (-)
Z1 - Z2 Lowvoltagelight(24V)
Z3 Motor 1 (OPENING)
Z4 Motor 1 (CLOSING)
Z5 Motor 2 (OPENING)
Z6 Motor 2 (CLOSING)
B1 - B2 230VACcourtesylightorashinglight
POW+ +24Vpowersupply
POW- Powersupply(-)
BAT+ +poleoftheoptionalbatterypack(code161212)
ortheECO-LOGICbatterybox
BAT- -poleoftheoptionalbatterypack(code161212)or
theECO-LOGICbatterybox
L Power phase 230 VAC
N Neutral 230 VAC
RECEIVER Pluginreceiver
ADI ADIinterface
OVERLOAD It shows that there is an overload on accessories
powersupply
MAINS It shows that the control unit is power supplied
F1 2,5A
K1 Open limit switch motor 1
Encoder
motor 2
K2 Close limit switch motor 1
K3 Open limit switch motor 2
Encoder
motor 1
K4 Close limit switch motor 2
K5 Common (-)
K6 Poweroutput+24Vdcforphotocellsandother
accessories
K7 Commonforaccessoriespowersupply
K8 Photocell/opticaledgeTXpowersupplyfor
functionaltest
K9 - K10 LOCK 12V
5.14 - ELECTRIC CONNECTIONS